20 D2-way flow control valverotary knob, setting angle 150°panel construction NG 8hole pattern according to Schiedrum standard13 nominal volume flow ranges 0,063 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax up to 450 bar
20 K2-way flow control valverotary knob, setting angle 300°panel construction NG 6hole pattern according to DIN 24 340-G67 nominal volume flow ranges 0,4 l/min up to 25 l/minminimal controllable volume flow approx. 15 cm3/minPmax = 315 bar
21 D2-way flow control valverotary knob, setting angle 150°front panel mounting with flangepipe connection13 nominal volume flow ranges 0,063 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax up to 210 bar
22 E2-way flow control valverotary knob, setting angle 150°front panel mounting without flangepipe connection13 nominal volume flow ranges 0,063 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax up to 210 bar
23 A2-way flow control valveram actuationwith/without roller leverpanel construction NG 8hole pattern according to Schiedrum standard8 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax = 210 bar
25 C2-way flow control valverotary knobfine actuation 3600° (10 turns)panel construction NG 6hole pattern according to DIN 24 340-G68 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax = 210 bar
26 GA2-way flow control valvemotorized actuation via stepper motorpanel construction NG 8hole pattern according to Schiedrum standard7 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10-20 cm3/minPmax = 210 bar
28 BD2-way flow control valveactuation via proportional solenoidpath sensorintegrated control electronicspanel construction NG 6hole pattern according to DIN 24 340-G66 nominal volume flow ranges 1 l/min up to 25 l/minminimal controllable volume flow approx. 10-20 cm3/minPmax = 210 bar
28 LR2-way flow control valveactuation via proportional solenoidcontrol loop via path sensorpanel construction NG 6hole pattern according to DIN 24 340-G66 nominal volume flow ranges 1 l/min up to 25 l/minminimal controllable volume flow approx. 10-20 cm3/minPmax = 210 bar
28 MP2-way flow control valveactuation via proportional solenoidpanel construction NG 6hole pattern according to DIN 24 340-G66 nominal volume flow ranges 1 l/min up to 25 l/minminimal controllable volume flow approx. 10-20 cm3/minPmax = 210 bar
30 D3-way flow control valverotary knob, setting angle 150°panel construction NG 8hole pattern according to Schiedrum standard7 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax up to 450 bar
31 D3-way flow control valverotary knob, setting angle 150°front panel mounting with flangepipe connection7 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10 cm3/minPmax up to 450 bar
35 A-C3-way flow control valverotary knobfine actuation 3600° (10 turns)panel construction NG 6hole pattern according to DIN 24 340-G613 nominal volume flow ranges 0,1 l/min up to 25 l/minminimal controllable volume flow approx. 10 cm3/minPmax = 210 bar
36 FA3-way flow control valvemotorized actuation via stepper motorpanel construction NG 8hole pattern according to Schiedrum standard7 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 1% of nominal volume flowPmax = 210 bar
38 CR3-way flow control valveactuation via proportional solenoidcontrol loop via path sensorpanel construction NG 6hole pattern according to DIN 24 340-G65 nominal volume flow ranges 1 l/min up to 30 l/minminimal controllable volume flow approx. 10-20 cm3/minPmax = 210 bar
38 DP3-way flow control valveactuation via proportional solenoidpanel construction NG 6hole pattern according to DIN 24 340-G65 nominal volume flow ranges 1 l/min up to 30 l/minminimal controllable volume flow approx. 10-20 cm3/minPmax = 210 bar
200 B2-way flow control valverotary knob, setting angle 150°panel construction NG 10hole pattern according to Schiedrum standard3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
200 B-Z2-way flow control valverotary knob, setting angle 150°sandwich plate construction NG 10hole pattern according to DIN 24 340-A10flow control in connection A and/or B3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
200 BP-TZ2-way flow control valverotary knob setting angle 150°sandwich plate construction NG 10hole pattern according to DIN 24 340-A10flow control in connection P or T3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
200 E2-way flow control valverotary knob, setting angle 150°panel construction NG 10hole pattern according to Schiedrum standard3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
201 D2-way flow control valverotary knob, setting angle 150°panel construction NG 24hole pattern according to Schiedrum standard2 nominal volume flow ranges 100 l/min up to 160 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
222 D2-way flow control valverotary knob, setting angle 150°for heavily contaminated mediumpipe connection12 nominal volume flow ranges 0,063 l/min up to 10 l/minminimal controllable volume flow approx. 5 cm3/minPmax up to 25 bar
261 FA2-way flow control valvemotorized actuation via stepper motorpanel construction NG 24hole pattern according to Schiedrum standard5 nominal volume flow ranges 25 l/min up to 160 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
265 D-DC2-way flow control valvemotorized actuation via 24 VDC motorpanel construction NG 8hole pattern according to Schiedrum standard7 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10-15 cm3/minPmax = 210 bar
266 D-DC2-way flow control valvemotorized actuation via 24 VDC motorpanel construction NG 15hole pattern according to Schiedrum standard3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
267 C-DC2-way flow control valvemotorized actuation via 24 VDC motorpanel construction NG 24hole pattern according to Schiedrum standard2 nominal volume flow ranges 100 l/min up to 160 l/minminimal controllable volume flow approx. 300 cm3/minPmax = 210 bar
280 BD2-way flow control valveactuation via proportional solenoidpath sensorintegrated control electronicspanel construction NG 10hole pattern according to Schiedrum standard3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
280 BP2-way flow control valveactuation via proportional solenoidpanel construction NG 10hole pattern according to Schiedrum standard3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
280 CP-Z2-way flow control valveactuation via proportional solenoidsandwich plate construction NG 10hole pattern according to DIN 24 340-A103 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
280 CR2-way flow control valveactuation via proportional solenoidcontrol loop via path sensorpanel construction NG 10hole pattern according to Schiedrum standard3 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
280 CR-Z2-way flow control valveactuation via proportional solenoidcontrol loop via path sensorsandwich plate construction NG 10hole pattern according to DIN 24 340-A103 nominal volume flow ranges 25 l/min up to 63 l/minminimal controllable volume flow approx. 200 cm3/minPmax = 210 bar
281 BP2-way flow control valveactuation via proportional solenoidpanel construction NG 24hole pattern according to Schiedrum standard2 nominal volume flow ranges 100 l/min up to 160 l/minminimal controllable volume flow approx. 300 cm3/minPmax = 210 bar
365 D-DC3-way flow control valvemotorized actuation via 24 VDC motorpanel construction NG 8hole pattern according to Schiedrum standard7 nominal volume flow ranges 1 l/min up to 16 l/minminimal controllable volume flow approx. 10-15 cm3/minPmax = 210 bar